世联博研(北京)科技有限公司 主营:Flexcell细胞力学和regenhu细胞3D生物打印机销售技术服务: 美国Flexcell品牌FX-5000T细胞牵张应力加载培养系统,FX-5K细胞显微牵张应力加载培养系统,Tissue Train三维细胞组织培养与测试系统,FX-5000C三维细胞组织压应力加载培养系统,STR-4000细胞流体剪切应力加载培养系统,德国cellastix品牌Optical Stretcher高通量单细胞牵引应变与分析系统 Regenhu品牌3D discovery细胞友好型3D生物打印机,piuma细胞纳米压痕测试分析、aresis多点力学测试光镊,MagneTherm细胞肿瘤电磁热疗测试分析系统
服务电话: 010-67529703
主营产品: Flexcell细胞力学和regenhu细胞3D生物打印机销售技术服务: 美国Flexcell品牌FX-5000T细胞牵张应力加载培养系统,FX-5K细胞显微牵张应力加载培养系统,Tissue Train三维细胞组织培养与测试系统,FX-5000C三维细胞组织压应力加载培养系统,STR-4000细胞流体剪切应力加载培养系统,德国cellastix品牌Optical Stretcher高通量单细胞牵引应变与分析系统 Regenhu品牌3D discovery细胞友好型3D生物打印机,piuma细胞纳米压痕测试分析、aresis多点力学测试光镊,MagneTherm细胞肿瘤电磁热疗测试分析系统
联系我们

Ligagen三维肌腱韧带应力培养系统,三维韧带牵张拉伸加载培养系统,LigaGen Tension Bioreactor System

  • 如果您对该产品感兴趣的话,可以
  • 产品名称:Ligagen三维肌腱韧带应力培养系统,三维韧带牵张拉伸加载培养系统,LigaGen Tension Bioreactor System
  • 产品型号:Ligagen
  • 产品展商:tissuegrowth
  • 产品文档:无相关文档
简单介绍

生物培养舱由生物相容性,高压**材料构成,LigaGen体外培养生物反应器提供轴向的压缩/拉伸应力刺激培养的样品。生物培养舱可以用于培养脱细胞的肌腱和韧带的各种结构材料的聚合物水凝胶。生物培养舱可容纳样本宽30毫米,厚3毫米。多种的固定装置应用于不同的样品,可以按照相关的研究思路去设定频率、振幅和载荷等。独特的生物培养舱密封条件,保证无菌环境下的培养,并把轴向运动的阻力降到*小。两种不同的生物培养

产品描述
 

LigaGen: Tension Bioreactor Systems

Watch a video of the LigaGen (L30-1) bioreactor.

BISS TGT series bioreactors provide mechanical stimulation to three dimensional tissue engineered constructs to create physiological conditions in-vitro. The LigaGen system imparts axial stress or strain to a ligament or tendon construct. The stress/strain profiles can be defined by the user and can be a simple harmonic (sinusoidal) or a physiological waveform. Applications include the investigation of cell function and differentiation, pharmaceutical benchtop testing, and the seeding and growth of engineered tissues and medical devices. Researchers are currently utilizing these systems in a wide range of research areas including:

  • ACL regenerative medicine
  • Collagen gel stimulation
  • Small diameter tendon stimulation
  • Hand tendon and ligament regenerative medicine

Chambers

The LigaGen bioreactor chamber delivers oscillatory axial stimulation to samples with large aspect ratios. The chambers can be used with a variety of construct materials from decellularized tendons and ligaments to polymerized hydrogels. The chamber accommodates samples up to 30mm in length and 3mm thickness. A wide range of construct geometries can be stimulated using multiple grip styles. A flexible bellows seal facilitates the transfer of axial motion into the chamber while maintaining a sterile environment. Single sample and multisample chamber configurations are provided and they can be used with a perfusion system to provide convective media transport around the samples. Fabricated from bioinert materials, the autoclavable chambers also polycarbonate removable windows for easy viewing and laser micrometer measurement. Additional chamber features include:

L30-1C:
Single sample chamber with 23ml internal volume
L30-4C:
The chamber accommodates either two (2) or four (4) samples and has an 80ml internal volume

 

Grip Options

The types of constructs used in ligament and tendon experiments vary widely and range from decellularized allografts to polymerized hydrogels. In order to handle these varied specimen types, the several options for gripping mechanisms are offered including:

40N Spring Assisted Wedge Action Grips
  • Designed specifically to secure your biological tissue for cell culture or characterization.  
  • The 4.8mm wide wedge shaped grips faces with gentle convolutions will secure slipper biological tissue. 
  • Accommodates samples up to 3mm thick and 4mm wide, made of passivated stainless steel for full submersion without corrosion.
  • Max force: 40N
  • Suitable for use in the L30-1 bioreactor chamber
40N Screw Action Grips
  • Simple and efficient biological tissue securement. These clamp grips are specifically designed to secure your biological tissue for cell culture or characterization.
  • Flat faces with serrated surfaces
  • 6mm wide or 10mm wide 
  • Made with electropolished titanium for full submersion without corrosion
  • Max force: 40N
  • Suitable for use in the L30-1 or L150-1 bioreactor chamber
In Situ Polymerization Grips
  • These grips feature an integrated construct mold and porous grip "face" to enable mechanical stimulation of hydrogel scaffolds
 

Bioreactor Stimulator:

The LigaGen bioreactor system includes the TC (tension/compression) mechanical stimulator. Featuring a 40N linear motor, the stimulator is lightweight, compact and incubator compatible. The TC stimulator controls both load and displacement and can be used with any of the LigaGen bioreactor chambers. The stimulator dimensions are as follows:

L30-1X Dimensions:
380mm(15")H X 127mm(5")W X 178mm(7")D
Weight 2.9kg (6.5lb)
L30-4C Dimensions:
330mm(13")H X 102mm(4")W X 102mm(4")D
Weight 2.3kg (5.0lb)
Ports:
5

 

GrowthWorks® Software & Control:

A fifth generation design, the GrowthWorks Software and Control platform includes advanced capabilities, such as multiple waveform control, data acquisition and multi-motor operation. The intuitive software runs on a Windows® laptop computer and features a simple user interface. User defined stimulation profiles are controlled by the software and are readily monitored using graphical displays. Integrated data acquisition routines capture and record data at user prescribed intervals. The GrowthWorks Software is configurable for running four stimulators while simultaneously monitoring up to 16 transducers, allowing the researcher maximum flexibility.

The GrowthWorks Control Hardware features an embedded Intel CPU, integrated data acquisition and integrated motor drives. Communications between the laptop and control hardware is transmitted over a standard network cable. Primary advantages of the TGT Laptop/Controller approach are reduced physical size and easy upgradability. As future Windows versions or higher performance Laptops become available, either can be replaced without any software or controller changes. This ensures the GrowthWorks control system will be an integral part of your research for many years to come.

GrowthApps Stiffness Measurement & Adaptive Control:

The GrowthApps modules provided added capability to GrowthWorks. The addition of the Stiffness Measurement & Adaptive Control Application enables the system to make real-time measurements of the sample stiffness during culture. Described in U.S. Patent 7,410,792 B2 Instrumented bioreactor with material property measurement capability and process-based adjustment for conditioning tissue engineered medical products., the Application measures the mechanical response of the tissue construct as it is being stimulated and conditioned. The stiffness measurements can be used as guidelines for bench marking progress during culturing or for modifying the stimulation profile. Based upon the measured response, the bioreactor system is then capable of altering the stimulation profile. This technology enables researchers to automatically culture the tendon or ligament from initial seeding to an implantation-ready state with minimal operator intervention.

LIGAMENT
Key: S=Standard, A=Available, - = not available
CHAMBERS L30-1 L30-4c
Individual ligament growth chamber S S
6 parallel growth chambers, with up to 4 ligament constructs per chamber - A
Interface for tension grips S S
Perfusion and instrumentation ports per chamber 4 4
Bellows and seal to protect construct from outer environment S S
In-situ hydrogel seeding configuration:  wire grips and casting mold A A
Patent pending grip lock during sample handling S S
Mechanical clamp grips A A
Inflatable clamp grips A A


STIMULATION    
Axial stimulator and reaction frame S S


CONTROLS    
Controller software, computer, and monitor S S
Power supplies and cabling S S
Automatic stimulation positioner - A
Mean flow control A A
Dynamic flow control A A


TISSUE MONITORING    
Non-contact radial or axial distension measurement A A
Non-contact flow sensors A A
Catheter pressure transducers A A


ACCESSORIES    
Media reservoir S S
Stimulator positioner (automatic) - A
Stimulator positioner (manual) - A
Incubator A A


BENEFITS    
All-autoclavable components S S
Excellent sample visibility S S
Medium change without opening chamber via luer injection port fittings S S
Increased sterility with fast and clean sample change and access S S
Lightweight design for easy handling S S
Easily cleaned surface finishes S S
Transparent opposing reactor walls for optical inspection or measurement S S
Compact design to fit in standard incubators S S
100% satisfaction guaranteed warranty S S
 

生物反应器:

1.        LigaGen生物反应器系统包括张力/压缩机械刺激器(T / C)

2.        2200 N直线电机

3.        刺激器是轻量级的,紧凑,耐腐蚀。

4.        兼容大多数标准的孵化器。

5.        TC刺激器控制荷载和位移,

6.        适用于任何LigaGen生物反应器腔。

培养室型号:

L30-1X:放入单一样品,可放入30mm长以及23ml的溶液;

L30-4C:放入2个或者4个样品, 80ml的溶液;

L150-1C :放入单一样品,可放入150mm长以及71ml的溶液。

生物培养舱由生物相容性,高压**材料构成,LigaGen体外培养生物反应器提供轴向的压缩/拉伸应力刺激培养的样品。生物培养舱可以用于培养脱细胞的肌腱和韧带的各种结构材料的聚合物水凝胶。生物培养舱可容纳样本宽30毫米,厚3毫米。多种的固定装置应用于不同的样品,可以按照相关的研究思路去设定频率、振幅和载荷等。独特的生物培养舱密封条件,保证无菌环境下的培养,并把轴向运动的阻力降到*小。两种不同的生物培养舱可以自由的选择是需要单一样品或多样品模拟刺激培养。

 

 

系统亮点:

1.        提供一个可控的3D环境,刺激体外生理条件。

2.        刺激器是轻量级的,紧凑,耐腐蚀。

3.         兼容大多数标准的孵化器。

4.        允许四个刺激器同时固定在标准的孵化器上.

5.         Windows®操作系统,直观的软件运行和功能,简单的用户界面。

6.        提供静态的或周期性振荡拉力。

7.         Growthworks®控制系统软件:多波形控制,数据采集和多电机运行控制。

 

产品留言
标题
联系人
联系电话
内容
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!
Copyright@ 2003-2024  世联博研(北京)科技有限公司版权所有      电话:13466675923 传真: 地址:北京市海淀区西三旗上奥世纪中心A座9层906 邮编:100096