世联博研(北京)科技有限公司 主营:Flexcell细胞力学和regenhu细胞3D生物打印机销售技术服务: 美国Flexcell品牌FX-5000T细胞牵张应力加载培养系统,FX-5K细胞显微牵张应力加载培养系统,Tissue Train三维细胞组织培养与测试系统,FX-5000C三维细胞组织压应力加载培养系统,STR-4000细胞流体剪切应力加载培养系统,德国cellastix品牌Optical Stretcher高通量单细胞牵引应变与分析系统 Regenhu品牌3D discovery细胞友好型3D生物打印机,piuma细胞纳米压痕测试分析、aresis多点力学测试光镊,MagneTherm细胞肿瘤电磁热疗测试分析系统
服务电话: 010-67529703
主营产品: Flexcell细胞力学和regenhu细胞3D生物打印机销售技术服务: 美国Flexcell品牌FX-5000T细胞牵张应力加载培养系统,FX-5K细胞显微牵张应力加载培养系统,Tissue Train三维细胞组织培养与测试系统,FX-5000C三维细胞组织压应力加载培养系统,STR-4000细胞流体剪切应力加载培养系统,德国cellastix品牌Optical Stretcher高通量单细胞牵引应变与分析系统 Regenhu品牌3D discovery细胞友好型3D生物打印机,piuma细胞纳米压痕测试分析、aresis多点力学测试光镊,MagneTherm细胞肿瘤电磁热疗测试分析系统
联系我们
产品中心

FUSInstruments代理,高强度聚焦超声系统

  • 如果您对该产品感兴趣的话,可以
  • 产品名称:FUSInstruments代理,高强度聚焦超声系统
  • 产品型号:RK-50
  • 产品展商:fusinstruments
  • 产品文档:无相关文档
简单介绍

FUSInstruments代理,RK-50台式血脑屏障超声系统 The focused ultrasound system that enables targeted brain exposures without the need for concurrent imaging

产品描述

Bench-top  focused ultrasound system


The focused ultrasound system that enables targeted brain exposures without the need for concurrent imaging.


The RK-50 is a stand-alone, versatile, preclinical system designed to take advantage of the various applications of focused ultrasound. Through the use of traditional stereotaxic targeting methods, the RK-50 can deliver precise doses of FUS through an intact skull to small structures in the rodent brain. The system can also be used to automatically raster a series of FUS exposures to cover an arbitrary volume. Applications include ablation, blood-brain barrier disruption, and neuromodulation.


Specifications:

  1. Precise, fast targeting with 3-axis positioning system
  2. Treatment planning software facilitates stereotaxic-guided target selection and exposure control (runs on included PC)
  3. Multi-point targeting is achievable in line, raster, and circular exposures
  4. Focused ultrasound dose settings can be easily controlled for any application
  5. Utilizes calibrated focused ultrasound transducers, available in a range of frequencies

















Studies using FUS Instruments’ Systems


Moyer, Linsey C., et al. “High-intensity focused ultrasound ablation enhancement in vivo via phase-shift nanodroplets compared to microbubbles.” Journal of Therapeutic Ultrasound 3.1 (2015): 7.


Ellens, N. P. K., et al. “The targeting accuracy of a preclinical MRI-guided focused ultrasound system.” Medical physics 42.1 (2015): 430-439.


Burgess, Alison, et al. “Alzheimer disease in a mouse model: MR imaging–guided focused ultrasound targeted to the hippocampus opens the blood-brain barrier and improves pathologic abnormalities and behavior.”Radiology 273.3 (2014): 736-745.


Diaz, Roberto Jose, et al. “Focused ultrasound delivery of Raman nanoparticles across the blood-brain barrier: Potential for targeting experimental brain tumors.” Nanomedicine: Nanotechnology, Biology and Medicine 10.5 (2014): 1075-1087.


Nance, Elizabeth, et al. “Non-invasive delivery of stealth, brain-penetrating nanoparticles across the blood− brain barrier using MRI-guided focused ultrasound.” Journal of Controlled Release 189 (2014): 123-132.


Oakden, Wendy, et al. “A non-surgical model of cervical spinal cord injury induced with focused ultrasound and microbubbles.” Journal of neuroscience methods 235 (2014): 92-100.

.


Phillips, Linsey C., et al. “Dual perfluorocarbon nanodroplets enhance high intensity focused ultrasound heating and extend therapeutic window in vivo.” The Journal of the Acoustical Society of America 134.5 (2013): 4049-4049.

.


Alkins, Ryan D., et al. “Enhancing drug delivery for boron neutron capture therapy of brain tumors with focused ultrasound.” Neuro-oncology (2013): not052.


Alkins, Ryan, et al. “Focused ultrasound delivers targeted immune cells to metastatic brain tumors.” Cancer research 73.6 (2013): 1892-1899.


Huang, Yuexi, Natalia I. Vykhodtseva, and Kullervo Hynynen. “Creating brain lesions with low-intensity focused ultrasound with microbubbles: a rat study at half a megahertz.” Ultrasound in medicine & biology 39.8 (2013): 1420-1428.


Jordão, Jessica F., et al. “Amyloid-β plaque reduction, endogenous antibody delivery and glial activation by brain-targeted, transcranial focused ultrasound.” Experimental neurology 248 (2013): 16-29.


Scarcelli, Tiffany, et al. “Stimulation of hippocampal neurogenesis by transcranial focused ultrasound and microbubbles in ***** mice.” Brain stimulation 7.2 (2013): 304-307.


Etame, Arnold B., et al. “Enhanced delivery of gold nanoparticles with therapeutic potential into the brain using MRI-guided focused ultrasound.” Nanomedicine: Nanotechnology, Biology and Medicine 8.7 (2012): 1133-1142.

 

Thévenot, Emmanuel, et al. “Targeted delivery of self-complementary adeno-associated virus serotype 9 to the brain, using magnetic resonance imaging-guided focused ultrasound.” Human gene therapy 23.11 (2012): 1144-1155.

 

Staruch, Robert, Rajiv Chopra, and Kullervo Hynynen. “Hyperthermia in Bone Generated with MR Imaging–controlled Focused Ultrasound: Control Strategies and Drug Delivery.” Radiology 263.1 (2012): 117-127.

 

Burgess, Alison, et al. “Targeted delivery of neural stem cells to the brain using MRI-guided focused ultrasound to disrupt the blood-brain barrier.” PLoS One 6.11 (2011): e27877.

 

Jordão, Jessica F., et al. “Antibodies targeted to the brain with image-guided focused ultrasound reduces amyloid-β plaque load in the TgCRND8 mouse model of Alzheimer’s disease.” PloS one 5.5 (2010): e10549.

 


Blood-Brain Barrier Disruption Studies


Leinenga, Gerhard, and Jürgen Götz. “Scanning ultrasound removes amyloid-β and restores memory in an Alzheimer’s disease mouse model.” Science translational medicine 7.278 (2015): 278ra33-278ra33.

 

Wang, S., et al. “Noninvasive, neuron-specific gene therapy can be facilitated by focused ultrasound and recombinant adeno-associated virus.” Gene Therapy 22.1 (2015): 104-110.

 

McDannold, Nathan, et al. “Temporary disruption of the blood–brain barrier by use of ultrasound and microbubbles: safety and efficacy evaluation in rhesus macaques.” Cancer research 72.14 (2012): 3652-3663.

 

Treat, Lisa H., et al. “Improved anti-tumor effect of liposomal doxorubicin after targeted blood-brain barrier disruption by MRI-guided focused ultrasound in rat glioma.” Ultrasound in medicine & biology 38.10 (2012): 1716-1725.
.

Kinoshita, Manabu, et al. “Noninvasive localized delivery of Herceptin to the mouse brain by MRI-guided focused ultrasound-induced blood–brain barrier disruption.” Proceedings of the National Academy of Sciences 103.31 (2006): 11719-11723.

 

Kinoshita, Manabu, et al. “Targeted delivery of antibodies through the blood–brain barrier by MRI-guided focused ultrasound.” Biochemical and biophysical research communications 340.4 (2006): 1085-1090.
.


Relevant Review Papers


Burgess, Alison, and Kullervo Hynynen. “Drug delivery across the blood-brain barrier using focused ultrasound.”Expert opinion on drug delivery 11.5 (2014): 711-721.

 

O’Reilly, Meaghan A., and Kullervo Hynynen. “Ultrasound enhanced drug delivery to the brain and central nervous system.” International Journal of Hyperthermia 28.4 (2012): 386-396.

 














产品留言
标题
联系人
联系电话
内容
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!
Copyright@ 2003-2024  世联博研(北京)科技有限公司版权所有      电话:13466675923 传真: 地址:北京市海淀区西三旗上奥世纪中心A座9层906 邮编:100096